OT/SCADA Security Assessment for a Fortune 500 Manufacturing Conglomerate
12 critical vulnerabilities found in industrial control systems including an air-gap bypass path
Client: Fortune 500 Manufacturing Conglomerate
The Challenge
IT/OT Convergence Created Unseen Attack Paths to Industrial Control Systems
A Fortune 500 manufacturer operating 14 production facilities across India had recently connected legacy SCADA systems to the corporate network for centralized monitoring. The OT team believed their air-gapped systems were secure, but the CISO suspected that IT/OT convergence had created attack paths that traditional IT security teams would not find.
- Legacy SCADA systems (some 15+ years old) now connected to corporate network
- No OT-specific security assessment ever conducted across any facility
- Production downtime costs exceeding INR 2 crore per hour at primary smelting facility
- Board-level concern after industry peer suffered ransomware-induced production shutdown
The Solution
Non-Intrusive OT Penetration Testing Across 3 Critical Facilities
Security Brigade deployed a specialized OT security team for non-intrusive assessment of SCADA, DCS, and PLC systems across 3 critical production facilities. The assessment combined passive network analysis, configuration review, and controlled active testing during scheduled maintenance windows — ensuring zero production impact.
Services used
Our approach
- 01 Phase 1: Passive OT network mapping — identified 340+ OT assets including 47 PLCs, 12 HMIs, and 8 SCADA servers with network taps
- 02 Phase 2: IT/OT convergence analysis — traced 6 paths from corporate network to OT zone, including 1 direct route via a misconfigured historian server
- 03 Phase 3: Controlled active testing during planned shutdown — tested PLC firmware, HMI web interfaces, and SCADA protocol authentication
- 04 Phase 4: Air-gap validation — demonstrated bypass via compromised engineering workstation with dual-homed network interfaces
The Results
12 Critical OT Vulnerabilities Remediated — Air-Gap Bypass Path Eliminated
Discovered 12 critical vulnerabilities including a complete air-gap bypass chain via a dual-homed engineering workstation. The historian server path alone could have given an attacker direct write access to PLC registers controlling furnace temperature. All critical findings remediated within 8 weeks.
Ready to discuss your security needs?
Talk to our team about a similar engagement for your organisation.
Request a Scoping Call